Section VII. CONTROL RECTIFIER, RECTIFIER ASSEMBLY, DIODES, CAPACITORS, AND RESISTORS
Figure 4-7. Rectifier assembly and diodes, removal and installation.

Gas Welding Machine, 300 Amp, 10 To 400 Amp, Ac, Str Polarity, 10 To 300 Amp Dc, Reverse Polarity
Page Navigation
  34    35    36    37    38  39  40    41    42    43    44  
img
. . . . . . . . . .
TM
5-3431-203-15
Figure 4-6. Control rectifier, removal and installation.
(2) Install the welding machine top and
b. Installation.
housing (para 3-26).
(1) Refer to figure 4-7 and install the
diodes.
4-24. Diodes
(2) Install the welding machine top and
housing (para 3-26).
a. Removal.
(1) Remove the welding machine top and
4-25. Capacitors
housing (para 3-26).
a. Removal.
(1) Remove and welding machine top
(2) Refer to figure 4-7 and remove the
and housing (para 3-26).
diodes.
4-7