c. Installation.
(1) Refer to figure 4-5 and install the in-
a. Removal.
tensity selector.
(2) Close and lock the panel door.
(1) Unlock the lower panel door.
intensity selector.
b. Testing.
(1) Connect an ohmmeter to the outside
terminals of the selector, and set the
meter on the RX1 scale. The read-
ing should be 2 ohms. If the read-
ing is more or less than 2 ohms re-
place the intensity selector.
terminal and either outside terminal.
Set the meter on the RX1 scale.
Turn the intensity selector in a clock-
wise direction until it stops; the me-
ter should have a zero reading. Then
turn the intensity selector in a coun-
terclockwise direction until it stops.
The reading should be 2 ohms. If
the readings are not as described, re-
place the intensity selector.
for the above tests is in proper working
condition.
installation.
Section VII. CONTROL RECTIFIER, RECTIFIER ASSEMBLY, DIODES,
CAPACITORS, AND RESISTORS
b. Installation.
a. Removal.
control rectifier.
(2) Install the welding machine top and
(1) Remove the welding machine top and
control rectifier.
a. Removal.
(1) Remove the welding machine top and
Warning: When malfunction of
the selenium rectifier occurs, thor-
oughly ventilate the area to prevent
rectifier assembly.
inhalation of poisonous fumes. Do
b. Disassembly and Reassembly. Refer to
not handle the damaged rectifier
while it is warm, to avoid absorption
the rectifier assembly.
of the poisonous selenium oxide com-
c. Installation.
pound through the skin. Failure to
observe this warning can result in
rectifier assembly.
serious injury or death.