Figure 4-4. Range switch, polarity switch, and control rheostat, removal and installation.
Figure 4-6. Control rectifier, removal and installation.

Gas Welding Machine, 300 Amp, 10 To 400 Amp, Ac, Str Polarity, 10 To 300 Amp Dc, Reverse Polarity
Page Navigation
  33    34    35    36    37  38  39    40    41    42    43  
img
. . . . . . . . . . . . . . .
TM
5-3431-203-15
c. Installation.
4-21. Intensity Selector
(1) Refer to figure 4-5 and install the in-
a. Removal.
tensity selector.
(2) Close and lock the panel door.
(1) Unlock the lower panel door.
(2) Refer to figure 4-5 and remove the
intensity selector.
b. Testing.
(1) Connect an ohmmeter to the outside
terminals of the selector, and set the
meter on the RX1 scale. The read-
ing should be 2 ohms. If the read-
ing is more or less than 2 ohms re-
place the intensity selector.
(2) Connect the ohmmeter to the center
terminal and either outside terminal.
Set the meter on the RX1 scale.
Turn the intensity selector in a clock-
wise direction until it stops; the me-
ter should have a zero reading. Then
turn the intensity selector in a coun-
terclockwise direction until it stops.
The reading should be 2 ohms. If
the readings are not as described, re-
place the intensity selector.
Note. Make sure that the ohmmeter used
for the above tests is in proper working
Figure 4-5. Intensity selector, removal and
condition.
installation.
Section VII. CONTROL RECTIFIER, RECTIFIER ASSEMBLY, DIODES,
CAPACITORS, AND RESISTORS
b. Installation.
4-22. Control Rectifier
(1) Refer to figure 4-6 and install the
a. Removal.
control rectifier.
(2) Install the welding machine top and
(1) Remove the welding machine top and
housing (para 3-26).
housing (para 3-26),
(2) Refer to figure 4-6 and remove the
4-23. Rectifier Assembly
control rectifier.
a. Removal.
(1) Remove the welding machine top and
Warning:  When malfunction of
housing (para 3-26).
the selenium rectifier occurs, thor-
(2) Refer to figure 4-7 and remove the
oughly ventilate the area to prevent
rectifier assembly.
inhalation of poisonous fumes. Do
b. Disassembly and Reassembly. Refer to
not handle the damaged rectifier
figure 4-8 and disassemble and reassemble
while it is warm, to avoid absorption
the rectifier assembly.
of the poisonous selenium oxide com-
c. Installation.
pound through the skin. Failure to
observe this warning can result in
(1) Refer to figure 4-7 and install the
rectifier assembly.
serious injury or death.
4-6