connector backshell as new connector is assembled to
(2) Inspect for damaged or loose connector
the wire harness.
pins and damaged wires. Check for any evidence of
burned areas indicating shorts. Inspect connectors for
(4) If self-clinching cable straps are removed
damaged or stripped threads.
to facilitate repairs, install new cable straps at five inch
intervals and at all cable breakouts.
d. Testing. Refer to the wire run chart in figure
f. Installation. Install the wire harness assembly in
reverse order of removal procedure. After installing
e. Repair, Replacement and Reassembly.
connector, safety wire in accordance with MS35540
(1) Solder connections will be made in
using lockwire MS20995C20.
accordance with MIL-S-6872 using solder Type
5-19.
Compressors Wire Harness Assemblies
SN60OWRP2 per Fed Spec QQ-S-571.
(13217E3796 and 13217E41551
(2) Replace defective wires with wire in
accordance with MIL-W-5086, Type II. Wire size and
harness assembly as follows: (I) Remove lockwire and
(3) If replacement of connectors P97 and P98
disconnect con
is necessary, install sleeving over exposed threads of
5-24