Figure 5-9. Recirculating fans wire harness assembly.
b. Disassembly. After inspection and testing,
(1) Solder connections will be made in
accordance with MIL-S-6872 using solder type
disassemble the wire harness only as required for
SN60OWRP2 per Fed Spec QQ-S-571.
repair or replacement.
(2) Replace defective wires with wire in
accordance with MIL-W-5086, Type II. Wire size and
c. Cleaning and Inspection.
approximate length in inches is provided in figure 5-9.
(3) If self-clinching cable straps are removed
(1) Clean wire harness with a clean, lint-free
to facilitate repairs, install new cable straps at five inch
cloth moistened with approved cleaning solvent and
intervals and at all cable breakouts.
dry thoroughly.
(2) Inspect for damaged or loose connector
f. Installation. Install the wire harness assembly
pins.
Check for any evidence of burned areas
in reverse order of removal procedure. After installing
indicating shorts. Inspect connectors for damaged or
connectors, safety wire in accordance with MS33540
stripped threads.
using lockwire MS20995C20.
d. Testing.
Refer to
the wire run chart in
figure 5-9
5-11. Recirculating Fans Wire Harness Assembly
(13217E4141)
e. Repair, Replacement and Reassembly.
the recirculating fans wire harness
5-13