TM   1-4920-455-13&P
3-17. Fixtures - Air Feed Thru Connector - Replace (Cont)
3-17
3.  Manufacture new connector (5) IAW App F.
4.    Apply  adhesive  (Item  2,  App  E)  on  flat  side  of
connector collar (6) facing long end of connector (5).
5.    Install  new  connector  (5)  from  outside  of  shelter;
long end of nipple thru hole.
6.  Install six screws (1), lockwashers (2), washers (3)
and  nuts  (4).
END  OF  TASK
3-21