WARNING
TM   1-4920-455-13&P
3-20. Special Circuit Breaker for Electrlc Welder - Replace
3-20
This  tasks  covers:  Replacement  of  Circuit  Breaker
INITIAL   SETUP
Tools:
Basic Issue Items (BII) - App C
Multimeter,  NSN  6625-01-139-2512
Personnel   Required:
68F  Aircraft  Electrician
Reference   Information:
TM  55-1500-204-25/1
REPLACEMENT
HIGH   VOLTAGE   exists  in  the  electrical  system  of  this  shop.  All
electrical  inspections,  repairs  or  replacements  shall  be  performed  with
the   power   OFF   and   only   by   qualified   electricians.   Serious   shock
hazards exist which could result in serious injury or death to personnel.
1.  Removing  defective  circuit  breaker.
a.
b.
c.
Ensure 100 AMP power cable has been discon-
nected
Loosen two screws (1) holding wires at bottom of
circuit breaker (2).
Remove black (3) and red (4) wires from bottom of
circuit breaker (2).
GO TO NEXT PAGE
3-26