TM 1-4920-455-13&P
3-15. Fixtures -Water Feed Thru Connector - Replace (Cont)
3-15
3.  Manufacture new connector (5) IAW App F.
4.  Apply adhesive (Item 2, App E) on side of connector
collar (6) facing long end of connector (5).
5.  Install  new  connector  (5)  from  outside  of  shelter;
long end of nipple thru hole.
6.  Install  six  screws  (1),  lockwashers  (2),  washers  (3)
and nuts (4).
END OF TASK
3 - 18