TM 1-4920-455-13&P
3-14.  Fixtures  -  Water  Feed  Thru  Connector  -  Inspect
3-14
This tasks covers: Inspection of connector
INITIAL   SETUP
44B Welder
Personnel   Required:
INSPECT  WATER  FEED  THRU  CONNECTOR
1.
2.
Remove dust caps (1), faucet (2) or adapter (3) from
connector (4).
Inspect  condition  of  connector  threads  (5).  Inspect
connector  weld  (6)  for  cracks  or  breaks.  Replace
IAW Task 3-15, if defective.
3.  Install  faucet  (2)  and  adapter  (3)  as  necessary.
4.  Ensure  dust  caps  (1)  are  installed  when  connector
(4) is not in use.
END OF TASK
3-16