a. Removal.
f. Installation. Install the wire harness assembly in
reverse order of removal procedure. After installing
disconnect the DC power branched wire harness
assembly as follows:
connectors, safety wire in accordance with MS33540
using lockwire MS20995C20.
(1) Remove lockwire and disconnect P65;
then remove connector J65 from the floor of the No. 2
5-4. DC Power Branched Wire Harness Assembly
system condenser compartment by removing four nuts
(13217E4149)
and screws and eight washers.
(2) Inspect for damaged or loose connector
(2) Disconnect leads to switches (S28 and
pins and terminal lugs. Check for any evidence of
S34).
burned areas indicating shorts.
Inspect wiring for
(3) Remove four cable clamps; note the
damaged insulation and loose connections. Inspect
position of the clamps and routing of the wire harness.
connectors for damaged or stripped threads.
(4) Remove the wire harness.
d. Testing.
Refer to
the wire run chart in
figure 5-3
b. Disassembly.
After inspection and testing,
disassemble the wire harness only as required for repair
or replacement.
e. Repair. Replacement and Reassembly.
c. Cleaning and Inspection.
(1) Solder connections will be made in
accordance with MIL-S-6872 using solder type
SN60WiRP2 per Fed Spec QQ-S-571.
(1) Clean wire harness with a clean, lint-free
cloth moistened with approved solvent and dry
(2) Replace defective wires with wire in
thoroughly.
accordance with MIL-W-5086, Type II. Wire size and
approximate length in inches in provided in figure 5-3.
5-5