Figure 3. Door Lock Tabs Installation.
Figure 2. Disassembly of Water Feed-thru Connector Assembly.

Maintenance Manual For Machine And Welding Shop Part No. 1035458 Part No. Sc4920-99-Cla63
Page Navigation
  232    233    234    235    236  237  238    239    240    241    242  
img
. . .
TM 1-4920-434-13&P
0063 00
FIELD MAINTENANCE
MACHINE AND WELDING SHOP SHOP
MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (2)
General Mechanics Tool Kit
(WP 0073 00, Table 2, Item 104 )
Equipment Condition
Materials/Parts
Functional
Compound, Caulking (WP 0079 00, Item 1)
INSPECTION OF INSTALLED ITEMS
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 1.
Inspect Water Feed-Thru Connector Assembly.
1.
Inspect condition of threads on both ends of water feed-thru connector (Figure 1, Item 1).
2.
Replace if damage is detected.
3.
Ensure that protective dust caps (Figure 1, Item 2) are attached.
4.
Ensure that weld on connector is not cracked or broken. Replace if defective.