MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES

Maintenance Manual For Machine And Welding Shop Part No. 1035458 Part No. Sc4920-99-Cla63
Page Navigation
  231    232    233    234    235  236  237    238    239    240    241  
img
TM 1-4920-434-13&P
0062 00
INSTALLATION CONTINUED
DOOR LOCK TABS CONTINUED
Figure 3.
Door Lock Tabs Installation.
6.
Pull rivets (Figure 3, Item 2) to secure door lock tabs (Figure 3, Item 1) to door.
7.
Weld door lock tabs (Figure 3, Item 1) to door in two places IAW TM 1-1500-204-23.
8.
Apply a bead of polysulide sealant along remaining two sides (Figure 3, Item 3) of door lock tabs (Figure 3,
Item 1) as well as coating rivet heads (Figure 3, Item 2) with polysulide sealant.
9.
Prime and paint IAW TM 43-0139.
END OF WORK PACKAGE
0062 00-3/4 blank