Figure 6-9. Schematic wiring diagram.
1. With the temperature of thermal
(g)
Dimensionally inspect the rotor as
protector at 77F (25C), pass a current of 25 amperes
of 115 vac through protector within one minute contacts
(h)
Inspect housing (30, fig.
must close.
2. Heat thermal protector to 307 to
333F (152.8to 166.7C); contacts must be open.
leads. Check the dc resistance of each coil; resistance
3. Remove thermal protector from test
of each coil must be 0.50 to 0.62 ohm.
circuit.
(f) Inspect end bell (23, 24) in accordance
"A" DIAMETER AND "C" SURFACE ESTABLISH
(22, fig. 6-7) in each end bell (23, 24) for security of
CENTER-LINE.
attachment and damage.
"B" DIAMETER MUST BE CONCENTRIC WITH "A"
DIAMETER WITHIN 0.001 INCH TOTAL INDICATOR
READING.
A
B
1.5750
4.561
IN.
IN.
1.5754
4.562
ME-5-6115-434-35/6-34
Figure 6-10. End bell inspection requirements.
6-22