• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 8. Daily preventive maintenance services..
Figure 9. Quarterly preventive maintenance services.

Welding M Arc: Generator, Electric Motor Driven, 300 Amp Dc, Arc, 220/440 60 Cycle, 3 Phase, Wheel Mounted
Page Navigation
  12    13    14    15    16  17  18    19    20    21    22  
img
. . .
Section III. OPERATOR MAINTENANCE
b. Remove the generator end cover (para 53).
38. General
c. Raise the excitation brush from the commutator
The instructions in this section are published for the
(para 56).
information and guidance of the operator to maintain the
welding machine.
d. Connect the negative terminal of a 6- to 12-volt
battery to the excitation brush stud.
39. Correcting Polarity
e. Touch the positive terminal of the battery to the
The welding generator terminals have been marked
bottom main brush stud for approximately 2 seconds.
for straight polarity (electrode terminal negative). If the
f.
Lower the excitation brush and replace the
polarity should become reversed, it may be corrected
generator end cover. The polarity will be correct when
after the motor has stopped.
the welding machine is next used.
g. Remove the cause of reversal in polarity.
a. Adjust the current selector for maximum current with
(Refer to Troubleshooting para 40).
electrode selector on any setting.
AGO 8244A
18