Figure 3. Door Lock Tabs Installation.
Figure 2. Disassembly of Water Feed-thru Connector Assembly.

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  227    228    229    230    231  232  233    234    235    236    237  
img
. . .
TM 1-4920-445-13&P
0055 00
FIELD MAINTENANCE
COMPOSITE SHOP
MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (2)
General Mechanics Tool Kit
(WP 0065 00, Table 2, Item 104 )
Equipment Condition
Materials/Parts
Functional
Compound, Caulking (WP 0071 00, Item 1)
INSPECTION OF INSTALLED ITEMS
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 1.
Inspect Water Feed-Thru Connector Assembly.
1.
Inspect condition of threads on both ends of water feed-thru connector (Figure 1, Item 2).
2.
Replace if damage is detected.
3.
Ensure that protective dust caps (Figure 1, Item 1) are attached.
4.
Ensure that weld on connector is not cracked or broken. If defective, replace.