MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  226    227    228    229    230  231  232    233    234    235    236  
img
TM 1-4920-445-13&P
0054 00
INSTALLATION CONTINUED
DOOR LOCK TABS CONTINUED
Figure 3.
Door Lock Tabs Installation.
6.
Pull rivets (Figure 3, Item 2) to secure door lock tabs (Figure 3, Item 1) to door.
7.
Weld door lock tabs (Figure 3, Item 1) to door in two places IAW TM 1-1500-204-23.
8.
Apply a bead of polysulide sealant along remaining two sides (Figure 3, Item 3) of door lock tabs (Figure 3,
Item 1) as well as coating rivet heads (Figure 3, Item 2) with polysulide sealant.
9.
Prime and paint IAW TM 43-0139.
END OF WORK PACKAGE
0054 00-3/4 blank