• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 6. Attach Water Feed-Thru Connector Assembly.
Figure 9. Removal of Air Feed-thru Connector Assembly.

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  232    233    234    235    236  237  238    239    240    241    242  
img
0055 00
TM 1-4920-445-13&P
INSPECTION OF INSTALLED ITEMS
AIR FEED-THRU CONNECTOR ASSEMBLY
Figure 7.
Inspect Air Feed-thru Connector Assembly.
1.
Inspect condition of threads on both ends of air feed-thru connector assembly (Figure 7, Item 1).
2.
Replace if damage is detected.
3.
Ensure that protective dust caps (Figure 7, Item 2) are attached.
4.
Ensure weld on connector is not cracked or broken. If defective, replace.
REMOVAL
AIR FEED-THRU CONNECTOR ASSEMBLY
Figure 8.
Disassembly of Air Feed-thru Connector Assembly.
1.
Have assistant hold nut (Figure 8, Item 4) and washer (Figure 8, Item 2) inside shelter.
2.
Remove nuts (Figure 8, Item 4), lat washers (Figure 8, Item 2), lock washers (Figure 8, Item 3), and screws
(Figure 8, Item 1), releasing air feed-thru connector assembly (Figure 8, Item 5).
0055 00-6