• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR MACHINIST VISE AND HARDWARE
MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE - Continued

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  200    201    202    203    204  205  206    207    208    209    210  
img
. . . .
TM 1-4920-445-13&P
0048 00
FIELD MAINTENANCE
COMPOSITE SHOP
MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (2)
General Mechanics Tool Kit
(WP 0065 00, Table 2, Item 104 )
References
Torque Wrench, 0-600 in. lbs
Sperian Fendall Pure Flow 1000 Eyewash Station
(WP 0065 00, Table 2, Item 110 )
Owner s Manual
Materials/Parts
Equipment Condition
Fountain, Eye and Face Wash (WP 0071 00, Item 4)
Eyewash Station Removed
INSPECTION OF INSTALLED ITEMS
NOTE
During installation of components same hardware should be used so as to maintain original
integrity of shop set.
Figure 1.
Eyewash Station.
1.
Inspect eyewash station bracket (Figure 1, Item 4) for damage. Replace as necessary.
2.
Inspect eyewash station bracket hardware (Figure 1, Item 1 through 3) for rust, cracks and rounded heads.
Replace as necessary.
REMOVAL
1.
If necessary, drain eye and face wash fountain solution IAW Eyewash Station Owner s Manual.
2.
Remove two bolts (Figure 1, Item 1), two lock washers (Figure 1, Item 2), two lat washers (Figure 1, Item 3),
and eyewash station bracket (Figure 1, Item 4).