• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR 60 AMP RECEPTACLE - Continued
MAINTENANCE INSTRUCTIONS FOR 240V OUTLET BOX ASSEMBLY AND COVER - Continued

Maintenance Manual For Machine And Welding Shop Part No. 1035458 Part No. Sc4920-99-Cla63
Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
img
. . .
TM 1-4920-434-13&P
0059 00
FIELD MAINTENANCE
MACHINE AND WELDING SHOP
MAINTENANCE INSTRUCTIONS FOR 240V OUTLET BOX ASSEMBLY AND COVER
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (1)
Electrical Repairers Tool Kit
Equipment Condition
(WP 0073 00, Table 2, Item 103 )
Functional
Multimeter (WP 0073 00, Table 2, Item 106 )
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
NOTE
During installation of components same hardware should be used so as to maintain original
integrity of shop set.
INSPECTION OF INSTALLED ITEMS
240V OUTLET BOX ASSEMBLY
Figure 1.
240V Outlet Box.
1.
Move main circuit breaker to OFF position.
2.
Inspect 240V outlet box assembly (Figure 1, Item 2) and cover (Figure 1, Item 3) for damage.
3.
Replace 240V outlet box assembly (Figure 1, Item 2) and/or cover (Figure 1, Item 3) if damage is detected.