Figure 2. Inspect 45 Degree Angle Adapter.
Figure 5. 45 Degree Angle Adapter Removal from Power Entry Panel Cover.

Maintenance Manual For Machine And Welding Shop Part No. 1035458 Part No. Sc4920-99-Cla63
Page Navigation
  208    209    210    211    212  213  214    215    216    217    218  
img
0058 00
TM 1-4920-434-13&P
REMOVAL CONTINUED
REMOVE CONTINUED
1.
Move main circuit breaker to OFF position.
2.
Remove four machine screws (Figure 3, Item 1) attaching 60 amp receptacle (Figure 3, Item 2) to 45 degree
angle adapter (Figure 3, Item 3).
3.
With machine screws (Figure 3, Item 1) removed, pull 60 amp receptacle (Figure 3, Item 2) out of 45 degree
angle adapter (Figure 3, Item 3) until wire lug terminals (Figure 3, Item 5) and wires (Figure 3, Item 4) are
exposed.
Figure 4.
45 Degree Angle Adapter Replacement.
NOTE
Receptacle lugs are identiied by letters "X", "Y", and "Z" with ground connection being identiied
by color green. Black wire will be attached to "X", red wire will be attached to "Y", and blue wire
will be attached to "Z".
4.
Loosen all lugs (Figure 4, Item 3) on 60 amp receptacle (Figure 4, Item 1) and remove wires (Figure 4, Item
2).