Figure 2. Wall and Floor Insert Inspection.
MAINTENANCE INSTRUCTIONS FOR BAYONET NEILL-CONCELMAN (BNC) CONNECTOR ASSEMBLY - Continued

Maintenance Manual For Machine And Welding Shop Part No. 1035458 Part No. Sc4920-99-Cla63
Page Navigation
  199    200    201    202    203  204  205    206    207    208    209  
img
. . .
TM 1-4920-434-13&P
0056 00
FIELD MAINTENANCE
MACHINE AND WELDING SHOP SHOP
MAINTENANCE INSTRUCTIONS FOR BAYONET NEILL-CONCELMAN (BNC) CONNECTOR ASSEMBLY
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (1)
Electrical Repairers Tool Kit
Equipment Condition
(WP 0073 00, Table 2, Item 103 )
Functional
Multimeter (WP 0073 00, Table 2, Item 106 )
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
NOTE
During installation of components same hardware should be used so as to maintain the original
integrity of the shop set.
INSPECTION OF INSTALLED ITEMS
Figure 1.
Inspect and Test BNC Connector Assembly.
1.
Move main circuit breaker to OFF position.