Figure 5-15. Condenser fans wire harness assembly.
c. Cleaning and Inspection.
d. Testing. Refer to the wire run chart in figure
(1) Clean wire harness with a clean, lint-free
cloth moistened with an approved solvent and dry
e. Repair. Replacement and Reassembly.
thoroughly.
(2) Inspect for damaged or loose connector
(1) Solder connections will be made in
pins and damaged wires. Check for any evidence of
accordance with MIL-S-6872 using solder Type
burned areas indicating shorts. Inspect connectors for
SN)OWRP2 per Fed Spec QQ-S-571.
damaged or stripped threads.
(2) Replace defective wires with wire in
accordance with MIL-W-5086,Type II. Wire size and
5-20