INTRODUCTION
Section I. GENERAL
maintenance will be only those prescribed in TM 38-
This publication contains descriptive data and in-
750.
formation for installing, operating, and maintain-
b. Report of errors, omissions, and recommenda-
ing Model MD301 FED Inert Shielded Arc Welding
tions for improving this publication by the individual
user is encouraged. Reports should be submitted on
ter 2 contains
instructions for installation and oper-
DA Form 2028 (Recommended Changes to Publica-
ation. Chapters 3 through 7 contain information on
tions) and forwarded direct to Commanding Gen-
preventive maintenance, troubleshooting, disassem-
eral, U. S. Army Mobility Equipment Command,
bly, and repair for various levels of maintenance.
ATTN: AMSME-MPP, 4300 Goodfellow Boulevard,
St. Louis, Mo. 63120.
a. DA Forms and records used for equipment
Section II. DESCRIPTION AND DATA
vided. It can also operate as a shielded metal arc
welder.
a. The Eutectic MD301 FED, general and inert
b. The high frequency and three timer controls
gas shielded arc welding machine (fig. 1-1 and 1-2),
which individually control the post-flow of gas and
hereafter called the welding machine, is operated
water; preflow of inert gas and spot arc timing are
from an external power source of either 230 or 460
located in a drawer-type frame at the top of the
volts alternating current and by single phase con-
welding machine. The drawer is removable for ease
nection. The welding machine can operate as a tung-
of maintenance.
sten inert gas (TIG) welder when water, inert gas
(such as argon or helium) and a TIG torch are pro-