TM 1-4920-455-13&P
2-10.  Positioning  Shop  Equipment  for  Transport.  The  following  procedures,  and  recommended  sequence,  for
moving  equipment  from  the  operational  mode  to  the  transport  or  storage  mode  will  be  observed.
a.   Removing   Welding   Exhaust   Fan.
1.  Ensure  exhaust  fan  control  switch  is  set  to
OFF  and  Disconnect  exhaust  fan  power  supply  cord.
2.  Loosen  and  remove  four  bolts  (1),  lock-
wahsers  (2),  and  washers  (3)  from  brackets  (4)  secur-
ing  welding  exhaust  duct  assembly  (5)  to  shelter  wall.
Remove  duct  assembly  and  set  aside.
3.  Remove  exhaust  fan  (6)  from  shelter  wall  and
store  in  overhead  rack  (7).
2-28