Figure 7. Ether primer, operating instructions.
Table II. Recommended Current Per Electrode Size.

Diesel Welding Machine, Arc Generator,300 Amp, Dc, Arc; Skid Mtd, 60 Amp, 2 375 Amp At 40 V Max Current, 115 V, 3 Kw
Page Navigation
  9    10    11    12    13  14  15    16    17    18    19  
img
OPERATION AS AN ARC WELDER.
STEP 1. REFER TO PAR. 13 AND START ENGINE.
STEP 2. ATTACH LUG END OF WORK CABLE TO WORK TERMINAL AND CLAMP END TO WORK METAL.
STEP 3. ATTACH LUG END OF ELECTRODE CABLE TO ELECTRODE TERMINAL.
STEP 4. PLACE POLARITY SWITCH IN NEGATIVE OR POSITIVE POSITION, DEPENDING ON ELECTRODE TO BE
USED.
STEP 5. PLACE JOB SELECTOR IN PROPER POSITION FOR WELD TO BE MADE.
STEP 6. SET CURRENT CONTROL SO THAT COLORED ARROW OH HANDLE CORRESPONDS WITH THE COLOR
AT WHICH JOB SELECTOR IS SET.
OPERATION AS A DC GENERATOR.
STEP 1 REFER-TO PAR. 13 AND START ENGINE.
STEP 2. PLACE IDLE CONTROL SWITCH IN OFF POSITION.
STEP 3. PLACE AUXILIARY GENERATOR SWITCH IN ON POSITION.
EMC 3431-201-10/9
Figure 9. Operating instructions.
17