TM 1-4920-455-13&P
3-25.  Fixed  Equipment/Components  -  Removal/lnstallation  (Cont)
3-25
3.   REMOVE/INSTALL   CABINETS.
NOTE
Permanently  installed  cabinets  should  not  ordinarily  be  removed  or  relo-
cated.  However,  in  the  event  that  it  becomes  necessary  to  remove,
reinstall or replace cabinets within the shelter, care must be taken to
remove  all  bolts,  Iockwashers,  washers  and  nuts  and  save  them  for
reuse.  Cabinets  are  bolted  to  the  floor,  wall,  and  adjacent  cabinets.
Four cabinet styles are installed throughout the shop sets and may be
complexed  in  various  configurations.  All  mounting  holes  are  universal
and  cabinets  may  be  substituted  for  others  without  special  mounting
considerations.
a.  Remove  fixed  equipment  and  bench  tips  as  re-
quired.
b. Remove all bolts (1), lockwashers (2) and washers
(3)  from  cabinets.  Remove  cabinets  (4).
c. Reposition cabinets (4).
d. Install bolts (1), lockwashers (2) and washers (3).
END OF TASK
3-40