TM 5-6100-224-ESC
PROCEDURE
RATINGS
GREEN
AMBER
RED
erratic operation, vibration or
unusual noise. After completing
remaining operational checks, stop
engine and check for smooth
operation during wind-down.
Item 4.
LEAKAGE
With engine running inspect the fuel
No leakage.
Less than 3
More than 3 drops
lines, lubricating oil lines, fuel and oil
(May be moist
drops in a
in a 5 minute period.
tank, filters, oil cooler, accessory case
to touch, but
5 minute
Visible cracks or
and dual drive pad.
no droplet formation)
period.
deteriorated hoses.
Item 5.
INSTRUMENTS AND CONTROLS
During operation of the engine, inspect
All items
One or more items
Controlling or selector
and actuate to determine that the con-
operate property.
switch missing or
not listed in RED
trolling switches, selector switches and
that are not operating
inoperative.
circuit breakers are functioning properly
properly or missing.
on all systems (except the turbine
emergency switch). All instruments
functioning properly, all switches,
instruments and circuit breakers
mounted securely.
Item 6.
Operates properly.
Any one electrical
Unusual noise or
properly at rated output. Check AC
indicator or component
vibration. Generator
6