TM 5-3431-201-10
30. Operator's Daily Services
Intervals
a. General. The intervals at which specific daily
B
DA
Procedure
services are to be performed by the operator or crew are
indicated by an X in the appropriate block in figure 14 as
follows:
X
--
X
Tools and equipment. Make sure that all
tools and equipment issued with the
B-Before operation
unit are in serviceable condition, clean,
D-During operation
and properly stowed.
A-After operation
X
X
--
Unusual operation and noise. Make a
b. Additional Daily Services.
An X in the
visual inspection of the entire welding
appropriate column (s) indicates the interval at which
machine for loose mountings. Observe
the service is to be performed.
the unit while in operation for exces-
sive vibration, unusual noises, over-
Intervals
heating, or other defects. If defects are
B
DA
Procedure
present, shut down the engine and
correct any operational trouble or re-
X
X
X
Visual inspection. Make a complete visual
port the condition to organizational
inspection of the entire unit for miss-
maintenance.
ing parts, insecure mountings, or other
X
--
--
Tampering. Inspect to see whether the
damage. Correct all defects or report
welding machine has been tampered
them to organizational maintenance.
with or damaged. Do not operate until
X
X
X
Leaks, general. Inspect the entire unit
all deficiencies have been corrected.
for evidence of fuel, oil, or coolant
X
Cleaning. Clean all dirt, grease, or
leaks. Correct all defects or report them
other foreign matter for the welding
to organizational maintenance.
machine. Pay particular attention to
X
--
--
Lubrication. Lubricate the unit
in
the radiator core.
accord-
X
Protection. See that all doors and panels
ance with the current lubrication
are properly installed and latched. If
order.
the welding machine is outside, cover
X
--
--
Publications. Make sure that a copy of
with a suitable waterproof cover. If
this manual, the current lubrication
low temperatures are expected and
order, and DA Form 285 are on or with
antifreeze is not available, drain the
the welding machine and are in service-
able condition.
on the radiator to indicate that the
cooling system has been drained.
29