Figure 6. Electrical Plug Connector.
MAINTENANCE INSTRUCTIONS FOR CIRCUIT BREAKERS

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  219    220    221    222    223  224  225    226    227    228    229  
img
0052 00
TM 1-4920-445-13&P
INSTALLATION CONTINUED
ELECTRICAL PLUG CONNECTOR CONTINUED
4.
Install threaded sleeve (Figure 6, Item 9) into back shell (Figure 6, Item 8).
5.
Place locking washer (Figure 6, Item 10) inside of threaded sleeve (Figure 6, Item 9).
6.
Place threaded locking ring (Figure 6, Item 11) onto connector end (Figure 6, Item 12).
7.
Crimp ive pins (Figure 6, Item 1) onto ive wires (Figure 6, Item 2).
8.
Insert wires (Figure 6, Item 2) into rear of connector (Figure 6, Item 12) in the following order:
a.
Insert black wire into the A cup.
b.
Insert red wire into the B cup.
c.
Insert orange wire into the C cup.
d.
Insert white wire into the D cup.
e.
Insert green wire into the E cup.
9.
Ensure wires (Figure 6, Item 2) are properly secured into rear of connector (Figure 6, Item 12).
10. Tighten connector end (Figure 6, Item 12) into threaded sleeve (Figure 6, Item 9).
11. Tighten back shell (Figure 6, Item 8) onto threaded sleeve (Figure 6, Item 9).
12. Secure electrical plug connector (Figure 6, Item 13) to power cable (Figure 6, Item 4) by installing two cable
clamps (Figure 6, Item 6), two lat head screws (Figure 6, Item 5) and two threaded sleeve nuts (Figure 6,
Item 7).
13. Perform operational checks.
END OF WORK PACKAGE