Figure 5. Disconnecting PDB from Generator.
REMOVING LIGHTING

Machine/Welding Shop P/N Sc492099Cla63
Page Navigation
  122    123    124    125    126  127  128    129    130    131    132  
img
0032 00
TM 1-4920-445-13&P
REMOVING EXTERNAL GROUND ROD
NOTE
Shelter is grounded through externally connected power supply.
Figure 6.
Removing External Grounding Rod.
1.
On power entry panel (Figure 6, Item 1) remove nut (Figure 6, Item 2), lock washer (Figure 6, Item 3), and lat
washer (Figure 6, Item 4) from ground stud (Figure 6, Item 7).
2.
Disconnect ground cable lug (Figure 6, Item 5) from ground stud (Figure 6, Item 7).
3.
Replace lat washer (Figure 6, Item 4), lock washer (Figure 6, Item 3), and nut (Figure 6, Item 2) on ground
stud (Figure 6, Item 7).
4.
Remove grounding rod (Figure 6, Item 6 from ground.
5.
Store grounding rod assembly in secure storage location.
END OF WORK PACKAGE