TM 1-4920-434-13&P
0025 00
POSITIONING EYEWASH STATION ASSEMBLY AND BRACKET FOR TRANSPORT MODE (1035458)
Figure 2.
Secure Eyewash Station (1035458).
1.
Drain eye and face wash fountain solution from eyewash station (Figure 2, Item 8) IAW Sperian Fendall Pure
Flow 1000 Eyewash Station Owner s Manual.
2.
Remove eyewash station (Figure 2, Item 8) from eyewash station wall bracket (Figure 2, Item 4) and set
aside.
3.
Remove two bolts (Figure 2, Item 1), two lock washers (Figure 2, Item 2), two lat washers (Figure 2, Item 3),
and wall bracket (Figure 2, Item 4).
NOTE
Eyewash station wall bracket is stored inside eyewash station (Figure 3 and Figure 4).
4.
Store hardware in cotton mailing bag located in shelter BII box and store eyewash station wall bracket (Figure
2, Item 4) in eyewash station storage location.
5.
Store eyewash station (Figure 2, Item 8) at transport location on the side of cabinet (C) (Figure 2, Item 6).
6.
Remove cargo strap (Figure 2, Item 7) from secure storage location.
7.
Secure eyewash station (Figure 2, Item 8) to cabinet (C) (Figure 2, Item 6) with cargo strap (Figure 2, Item 7).
END OF WORK PACKAGE
0025 00-3/4 blank